EIFS & Dryvit Restoration in Suwanee
Suwanee office buildings, hotels and apartment communities from the 1990s and 2000s often wear EIFS that is reaching the end of its first life. We repair the damage, rebuild wet areas properly and recoat the system so it performs and looks current again.
- EIFS & Dryvit repair
- Joint & sealant renewal
- Facade recoats
- Drainable conversions
Request a commercial quote
Suwanee commercial stucco & EIFS. Property managers, boards, owners & builders.
Suwanee’s growth years were EIFS years
When Suwanee was adding office space along Peachtree Industrial Boulevard, hotels near I-85 and new apartment communities across the city, EIFS was one of the most common commercial claddings in Georgia. It was light, fast and could be shaped into cornices, bands and quoins that made a building look more expensive than it was. Much of it was installed as a barrier system, which relies on the outer surface and its sealant joints to keep every drop of water out.
That works until the sealant ages, a sign is added or a crack opens at a window corner. Then water gets behind the foam and has no way out, and the sheathing underneath stays wet.
EIFS restoration starts with finding where that has happened. We survey and probe the facade, open areas where readings are high and replace damaged sheathing before rebuilding foam, base coat, mesh and finish to match. Every joint on the building is replaced with sealant against the base coat, not the finish. Where an owner wants a long-term fix, we can discuss converting sections to a drainable assembly, and we finish with a recoat that unifies color across repaired and original areas.

EIFS & Dryvit restoration in Suwanee
Most EIFS problems come down to water at the edges or damage to a soft face. The scope depends on whether the substrate behind is still dry.
Wet substrate repair
Wet sections are cut out, damaged sheathing replaced with glass-mat gypsum board, and the wall rebuilt with new board, mesh, base coat and finish.
Joint & sealant renewal
Failed sealant at windows, storefronts and panel joints is replaced with backer rod and an EIFS-compatible sealant against a sound edge.
Facade recoats
A new finish coat over sound EIFS renews color and texture across an entire elevation or building without removing the system.
Barrier to drainable conversion
Failing barrier EIFS is removed and replaced with a drainable system over a weather barrier, elevation by elevation if needed.
Impact damage
Dents and punctures at entrances, loading areas and ground-floor corners are cut back, rebuilt with heavier mesh where needed and blended in.
Below-grade foam & termites
Foam board run into soil or under pavement gives termites a hidden path. We cut it back above grade and repair damaged framing.
Choosing the right EIFS scope
If moisture readings are low and damage is local, section repairs with new sealant joints and a matched finish are usually the right answer. If the facade has been patched many times or faded unevenly, a recoat across the elevation gives a uniform look and helps a dated building show better to tenants and prospects.
When barrier EIFS shows wet readings in many places, repairing spot by spot often just moves the problem. Converting to a drainable system, or to hard coat stucco or fiber cement on some elevations, can be the better long-term choice. We explain the options with readings and photos in front of you, separate urgent work from what can be phased, and document any change in scope for your approval before we proceed.
| Scope | Best for | Result |
|---|---|---|
| Section repair | Local damage, dry substrate | Blended to corners |
| Joint renewal | Failed sealant, sound wall | Edges closed |
| Facade recoat | Patched or faded elevations | Uniform building |
| Drainable conversion | Widespread wet barrier EIFS | New drainable system |
How an EIFS restoration runs
Restorations run elevation by elevation, so tenants and residents keep their entrances, parking and daily routine.
Identify & survey
We confirm whether the facade is barrier or drainable EIFS and take moisture readings to find the edges of any wet area on each elevation.
- System identified
- Readings mapped by elevation
- Photo documentation
Remove & rebuild
Damaged EIFS and wet sheathing come out. New sheathing, weather barrier and insulation board go in, with flashing corrected at the leak.
- Wet sheathing replaced
- Flashing corrected
- Foam kept above grade
Mesh, coat & finish
Base coat and reinforcing mesh are lapped into the existing wall, joints are sealed, and the finish is matched or the elevation recoated.
- Mesh lapped into old work
- Compatible materials
- Matched finish
Not sure if the building is EIFS or stucco?
EIFS sounds hollow and feels softer than cement stucco when tapped. We confirm it on the first site walk.
One era of buildings, one set of weak details
Buildings put up in the same decade tend to fail in the same places, and Suwanee has a lot of buildings from the same decade.
On Suwanee’s office parks and Gateway hotels, the EIFS problems repeat: window corners without sill pans, foam carried down into soil or onto roofs, decorative bands that hold water on top, and sign and light fixtures fastened through the finish. Knowing those patterns lets us test the right spots first and give owners a realistic picture of the scope early.
Barrier EIFS on offices
Office and flex buildings along Peachtree Industrial often use face-sealed EIFS with no drainage behind it.
Hotels near I-85
Multi-story hotel elevations collect water at window stacks and horizontal bands.
Dated finishes
Chalky, mismatched patches from years of spot repairs that a full recoat can unify.
- Suwanee
- Suwanee Gateway
- Peachtree Industrial Boulevard
- Old Town Suwanee
- Duluth
- Johns Creek
- Sugar Hill
- Buford
- Peachtree Corners
- Lawrenceville
EIFS and Dryvit questions in Suwanee
What Suwanee owners and managers ask about restoring an EIFS facade.
Do we need a permit to restore EIFS on our Suwanee building?
Our Suwanee building is near Town Center. Can we change the EIFS color?
Is Dryvit the same as EIFS?
Can barrier EIFS be converted to a drainable system?
How do we know how much of the EIFS is wet?
Restore your EIFS facade in Suwanee
Tell us about the building and what you are seeing. We will survey the EIFS and send a written restoration scope.